Sales hotline+86 135 1772 8899 | EmailQL8899@hotmail.com | WhatsApp+86 135 1772 8899
Genset HubDIESEL POWER · CHINA

Diesel generator prices from China: what the number is made of

A diesel genset price is not one figure — it is an engine, an alternator, a controller and an enclosure, plus the commercial terms around them. Two quotes for "a 200 kW set" can differ by 40 % and both be honest, because they are not the same set. Here is what moves the number.

Indicative FOB China prices, 50 Hz, 400/230 V

Standard configurations, standby rating, 0.8 power factor. Valid for 30 days as anchors, not as offers — the signed proforma invoice prevails.

RatingStandby kVATypical engineBuildFOB from (USD)
30 kW37.5Yuchai YC4FA75-D20Open / silent2,900
50 kW62.5Yuchai YC4D90Z-D20Silent4,200
80 kW100Weichai WP4D108E200Silent5,900
100 kW125Yuchai YC6B155-D20Silent7,300
120 kW150Weichai WP6D167E200Open6,900
200 kW250Yuchai YC6M350L-D20Silent11,500
200 kW250Cummins 6LTAA8.9-G2 + Leroy-SomerSilent18,900
250 kW312.5Weichai WP10D320E200Silent14,300
300 kW375Cummins NTA855-G4Open / container23,500
400 kW500Cummins KTA19-G4Silent / container33,500
500 kW625Cummins KTA19-G8Container40,500
800 kW1000Cummins KTA38-G5Container64,000

These are FOB, so they exclude ocean freight, insurance, duties and installation. Open-frame versions of the same set typically run 8–12 % below the silent figure. 60 Hz builds, CE configuration, non-standard voltages, ATS, synchronising panels and spare-parts kits are quoted separately.

Where the money goes

The split below is typical for a 200–400 kVA silent set. It is the fastest way to see why one quote is cheaper than another.

ComponentShare of priceWhere the savings hide
Diesel engine40–50 %Brand tier and whether it is genuine or a licensed copy
Alternator15–20 %Copper mass, insulation class, single vs double bearing, brand
Enclosure / canopy10–18 %Steel gauge, acoustic lining thickness, paint system
Controller and electrical5–8 %Deep-sea-class controller vs a generic panel; breaker brand
Radiator, exhaust, tank, wiring6–10 %Radiator core size and muffler grade
Factory test and documentation2–4 %Whether a load test was actually done, or just a start-up
Margin and overhead8–12 %—

The alternator line is where a 30 % gap usually appears. A set quoted with "100 % copper, class H, IP23" and a set quoted with "copper-clad aluminium" look identical in a photo and behave very differently at 80 % load for eight hours a day.

Seven variables that move the price

  1. Engine brand tier. A Cummins or Perkins platform typically adds 25–45 % over an equivalent Chinese platform at the same rating. You are buying dealer network, parts availability and resale value as much as iron.
  2. Rating definition. Standby (ESP), prime (PRP) and continuous (COP) are three different machines. A 250 kVA standby set is roughly a 200 kVA prime set. Compare like with like or the cheapest quote wins for the wrong reason.
  3. Voltage and frequency. 50 Hz 400 V is the volume build. 60 Hz, 380 V, 440 V, 480 V or 11 kV add engineering and a different alternator winding.
  4. Enclosure grade. Open, standard silent, super silent and container modules step up roughly 8–12 % each.
  5. Control and protection. A basic controller with start/stop is not the same as a paralleling controller with load sharing and remote monitoring.
  6. Certification. CE, EPA, or a client-specified third-party inspection adds cost — and a quote without it is not comparable to one with it.
  7. Volume and timing. A single unit ordered in the peak season costs more than the tenth unit in a batch, and steel and copper prices move the base cost quarterly.

FOB, CFR or CIF — and why the cheapest incoterm is not the cheapest deal

FOB means we deliver to the port and clear export. CFR adds ocean freight to your port. CIF adds freight and insurance. The set price is identical in all three; only the logistics wrapper changes. Ask for all three against your destination port — the freight component can be 8–20 % of the total and varies by a factor of two between routes and seasons.

Two traps. First, a CIF quote that looks low often uses a freight rate that will not hold at booking time; confirm the validity period. Second, DDP quotes with a very low duty assumption can leave you with a bill at customs — check the HS code and the declared value before you accept.

Why the lowest quote is usually the most expensive

We see this pattern in repair work more than anywhere else. A set bought 18 % cheaper arrives with: a smaller radiator that cannot hold 40 °C ambient, an alternator rated at 80 % of nameplate, no load test report, a controller whose manual does not exist in English, and a canopy whose paint fails in the first coastal season. The first two years it works. The third year it derates, overheats, and the parts cannot be matched.

Three things to demand before you compare prices: the factory load test report with the serial number on it, the alternator datasheet naming copper mass and insulation class, and the engine serial so you can verify the platform and its rating with the engine maker.

Send the load list, get a firm price in two hours

Tell us the required kW, voltage, frequency, application and destination port. We reply with a specification, a test report sample and FOB / CFR / CIF pricing — within two working hours, GMT+8.

Request a quotation See full model list

Questions buyers ask

Why is a 200 kW Cummins set almost twice the price of a 200 kW Chinese set?

Roughly: the engine platform costs more, the alternator is usually a branded unit rather than an OEM build, and there is a dealer network behind it. The gap narrows on total cost of ownership if you keep the set for 15 years and parts availability matters — and widens if the set runs 200 hours a year on standby.

Can you quote 60 Hz and 440 V for the same model?

Yes. It means a different engine rating point, a different alternator winding and often a different radiator. Expect 3–8 % above the 50 Hz figure, and a longer lead time because the configuration is not a stock build.

What is included in the FOB price?

The set as specified, factory load test, standard tool kit, English operation manual and wiring diagram, export packing (plywood case or steel frame), and delivery to the port with export clearance. Not included: ocean freight, insurance, destination charges, duties, offloading at site or installation.

How long is a quotation valid?

Thirty days as standard, because steel and copper move. For projects with a long approval cycle we can hold a price against a deposit, with the exchange-rate basis stated in the contract.